DALI-2 Sensor Interface to connect conventional motion sensors or pushbuttons to a DALI system 89453477
Lunatone
Part No
LEDDALI2SI
DALI-2 SI Multifunctional Sensor Module
Sensor Interface to connect conventional motion sensors or pushbuttons to a DALI system. Configuration options are for example: range, target address, DALI commands for on/off, hold time, etc. Multiple sensors within one group synchronise automatically. Two different versions are available: for potential free switching input (DALI SI - this one) and switching input for mains (DALI SI1L). The device is designed to fit behind a light switch in a flush-type box.
Product family overview:
Designed and made in the EU
Module with switching input for sensor input
Easy integration of occupancy and movement sensors, contact switches, photoelectric barrier sensors etc
Application controller: Movement triggered
Behaviour can be changed via scenes and external DALI commands
Corridor function – second light level before off in case of absence
Easy configuration via DALI-Cockpit Software Tool and Lunatone DALI USB interface LEDDALI2USB
Multiple modules can be installed within a DALI system
Version with potential free input (DALI-2 SI - this one) and with input for mains (DALI-2 SI- 1L) are available
Supply via the DALI bus, no additional power supply needed
Compact housing for back box installation
Article number: 89453477 (for potential free switching input sensors)
Output: DA+, DA-
Output type: DALI, DALI-2, Multimaster
Marking terminals: DA+, DA-
Voltage range: 9,5V … 22,5Vdc according to IEC62386
Typical current consumption DALI (16.5V): 5.1 mA
Max current consumption DALI (22.5V): 5.7 mA
DALI addresses: none
DALI-2 addresses: 1
Input
Input type: potential free switching input
Number of inputs: 1
Marking input terminals: T1, COM
Input voltage range: --
Input frequency: --
Input resistance: --
Minimum length of control pulse : 40ms
Max wire length: 5m
Insulation data
Impulse voltage category: II
Pollution degree: 2
Rated insulation voltage: 250V
Insulation: reinforced isolation DALI / housing
Insulation test voltage: 3000Vac DALI / housing
Environmental conditions
Storing and transportation temperature: -20°C … +75°C
Operational ambient temperature: -20°C … +60°C
Rel. humidity, none condensing: 15% … 90%
General data
Dimensions (l x w x h): 40 x 28 x 15 mm
Mounting: Back box installation, installation in protection class II devices
Rated max. temperature tc: 65°C
Expected life time @tc: 100000 h
Protection class: SKII (when used/installed as intended)
Protection degree: IP20
Terminals
Connection type: spring terminal connector
Wire size solid core: 0,5 … 1,5 mm2 (AWG20 … AWG16)
Wire size fine wired: 0,5 … 1,5 mm2 (AWG20 … AWG16)
Wire size using wire end ferrule: 0,25 … 1 mm2
Stripping length: 8,5 … 9,5mm / 0,33 … 0,37 inch
Release of wire: push mechanism
Standards
DALI: IEC62386-101:2014, IEC62386-103:2014, IEC62386-303
EMV: EN 61547, EN 50015 / IEC CISPR15
Safety: EN 61347-2-11, EN 61347-1
Markings: DALI-2, CE, UKCA
Sensor Interface to connect conventional motion sensors or pushbuttons to a DALI system. Configuration options are for example: range, target address, DALI commands for on/off, hold time, etc. Multiple sensors within one group synchronise automatically. Two different versions are available: for potential free switching input (DALI SI - this one) and switching input for mains (DALI SI1L). The device is designed to fit behind a light switch in a flush-type box.
Product family overview:
Designed and made in the EU
Module with switching input for sensor input
Easy integration of occupancy and movement sensors, contact switches, photoelectric barrier sensors etc
Application controller: Movement triggered
Behaviour can be changed via scenes and external DALI commands
Corridor function – second light level before off in case of absence
Easy configuration via DALI-Cockpit Software Tool and Lunatone DALI USB interface LEDDALI2USB
Multiple modules can be installed within a DALI system
Version with potential free input (DALI-2 SI - this one) and with input for mains (DALI-2 SI- 1L) are available
Supply via the DALI bus, no additional power supply needed
Compact housing for back box installation
Article number: 89453477 (for potential free switching input sensors)
Output: DA+, DA-
Output type: DALI, DALI-2, Multimaster
Marking terminals: DA+, DA-
Voltage range: 9,5V … 22,5Vdc according to IEC62386
Typical current consumption DALI (16.5V): 5.1 mA
Max current consumption DALI (22.5V): 5.7 mA
DALI addresses: none
DALI-2 addresses: 1
Input
Input type: potential free switching input
Number of inputs: 1
Marking input terminals: T1, COM
Input voltage range: --
Input frequency: --
Input resistance: --
Minimum length of control pulse : 40ms
Max wire length: 5m
Insulation data
Impulse voltage category: II
Pollution degree: 2
Rated insulation voltage: 250V
Insulation: reinforced isolation DALI / housing
Insulation test voltage: 3000Vac DALI / housing
Environmental conditions
Storing and transportation temperature: -20°C … +75°C
Operational ambient temperature: -20°C … +60°C
Rel. humidity, none condensing: 15% … 90%
General data
Dimensions (l x w x h): 40 x 28 x 15 mm
Mounting: Back box installation, installation in protection class II devices
Rated max. temperature tc: 65°C
Expected life time @tc: 100000 h
Protection class: SKII (when used/installed as intended)
Protection degree: IP20
Terminals
Connection type: spring terminal connector
Wire size solid core: 0,5 … 1,5 mm2 (AWG20 … AWG16)
Wire size fine wired: 0,5 … 1,5 mm2 (AWG20 … AWG16)
Wire size using wire end ferrule: 0,25 … 1 mm2
Stripping length: 8,5 … 9,5mm / 0,33 … 0,37 inch
Release of wire: push mechanism
Standards
DALI: IEC62386-101:2014, IEC62386-103:2014, IEC62386-303
EMV: EN 61547, EN 50015 / IEC CISPR15
Safety: EN 61347-2-11, EN 61347-1
Markings: DALI-2, CE, UKCA
| Poids | 10g |
|---|
Questions des clients
Écrivez votre propre avis
Pour obtenir des informations supplémentaires, notamment sur les prix et sur les stocks, veuillez nous contacter à l’aide du formulaire ci-dessous.
Pour obtenir des informations supplémentaires, notamment sur les prix et sur les stocks, veuillez nous contacter à l’aide du formulaire ci-dessous.
sgm_clp_1 div pour segmenter